Skip to main content
Schneider Electric MGN61889

MGN61889 Multi9 C60H-DC MCB, 40 A, 2P, K Curve, 20 kA DC

MPN MGN61889
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61889, miniature circuit-breaker, 2P, 40 A, K curve, 20 kA Icu at 250 V DC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61889 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61889 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric MGN61889 is a Multi9 C60H-DC miniature circuit-breaker for DC networks. It is a 2-pole, 40 A unit with a K trip curve, clips onto DIN rail, and occupies 4 modular pitches (36 mm wide, 81 mm tall, 73 mm deep). The thermal-magnetic trip unit handles the overload side; the magnetic element clears short-circuits. This is not a general-purpose AC breaker — it is rated and tested for DC only, with a utilisation category A per EN/IEC 60947-2. Breaking capacity is the key fit check: 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC. Rated insulation voltage (Ui) is 500 V DC, and the rated operational voltage (Ue) covers 220 V, 250 V, 440 V, and 500 V DC systems.

Mounts via clip-on to DIN rail. The terminals can also accept two or three conductors per pole — useful for daisy-chaining downstream loads without extra terminal blocks. IP20 on the terminals, IP40 on the modular enclosure — suitable for dry indoor panels. The toggle switch provides local ON/OFF indication, and the contact position indicator confirms isolation status (suitability for isolation is marked on the device). Padlockable for lockout/tagout.

Standards compliance: EN/IEC 60947-2. Tropicalisation per IEC 60068-2 (class 2) means it withstands humidity up to 95 % at 55 °C.