Schneider Electric MGP0801L2

MGP0801L2 PowerPacT 4 1P 80A Circuit Breaker, Obsolete

MPN MGP0801L2
Obsolete

Schneider Electric PowerPacT 4, molded case circuit breaker, 1P, L2 phase, 80 A at 40 °C, 230 V AC, 25 kA Icu, panel-mounted, obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGP0801L2 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui750 V
Phase connectionL2
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Thermal protection adjustment range80 A

Product details

The MGP0801L2 is a 1-pole molded case circuit breaker (MCCB) from the PowerPacT 4 range, rated 80 A at 40 °C with a TM-D thermal-magnetic trip unit providing LI protection — thermal overload (L) and magnetic short-circuit (I). It is designed for distribution applications and carries a 25 kA Icu and Ics at 230 V AC 50/60 Hz, with a rated insulation voltage of 750 V and impulse withstand of 8 kV. The toggle control type and backplate mounting suit panel-mounted distribution boards where a compact 1-module (35 mm) footprint is needed.

Lifecycle reality — obsolete, sourced through independent channels

This part is officially obsolete per the manufacturer's lifecycle status.

The thermal-magnetic LI trip responds to overload (thermal) and short-circuit (magnetic) currents; there is no earth-leakage protection built in. The Ics is equal at 25 kA, meaning it can also be reclosed after a fault at that level — useful for service-entrance or main-panel positions where fault current is high. The 750 V insulation rating and 8 kV impulse withstand cover it for most distribution panels. Electrical durability is 20,000 cycles at rated current, 10,000 cycles at In/2 — enough for a distribution breaker that cycles infrequently.

Conforms to BS EN 60947-2, the standard for low-voltage switchgear and controlgear. It is also suitable for isolation per that standard. Utilisation category A means it is not specifically intended for motor starting (category B would be for motor protection). Use it for cable and distribution protection.

MPN