Skip to main content
Schneider Electric MGP26500

MGP26500 PowerPact M Circuit Breaker, 500 A, 2-Pole, ET 1.0

MPN MGP26500
Obsolete

Schneider Electric PowerPact M, MGP26500, 2-pole 500 A circuit breaker, electronic ET 1.0 trip unit, 65 kAIC at 240 V AC, unit mount lug terminals, black.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGP26500 key specifications
ParameterValue
Control typeOperating handle
Trip unit typeElectronic, basic, ET 1.0
Main product or component typeCircuit breaker
Voltage600 V AC 50/60 Hz UL 489
Insulation voltage ui750 V IEC 60947-2
Poles2P
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-58...185 °F (-50...85 °C)

All specifications

MGP26500 additional specifications
ParameterValue
Pollution degree3 IEC 60947-1
ColorBlack
Depth8.05 in (204.47 mm)
Width8.27 in (210.06 mm)
Height12.86 in (326.64 mm)
AWG gauge3 x AWG 3/0...3 x 500 kcmil aluminium/copper
ApplicationDistribution
Operating temperature-13...158 °F (-25...70 °C)

Product details

The MGP26500 is a 500 A, 2-pole PowerPact M circuit breaker with an electronic ET 1.0 trip unit. The 65 kA AIR at 240 V AC (UL 489) and 35 kA at 480 V AC tell you it can handle high-fault-current panels without cascading upstream — critical for a main or large feeder in a distribution board. The IEC 60947-2 Icu of 50 kA at 240 V and 35 kA at 380/415 V means the same breaker meets both North American and international specs, so it fits a global BOM without a variant swap. The 80 % continuous current rating means the breaker is listed to carry 400 A continuously in a panel — not the full 500 A — unless you account for the 100 % rating option. That 80 % figure is the default for most UL 489 molded-case breakers; if your load pulls the full 500 A steady, you need to check the continuous-current derating for your enclosure and ambient.

This is a unit-mount breaker with lug terminals on line and load. The lug range accepts 3 x AWG 3/0 up to 3 x 500 kcmil aluminium or copper — sized for the 500 A feed. Tightening torque is 50 N·m (442.5 lbf·in) for the main conductors. Strip length is 25 mm (1.0 in). The IP40 front panel protection means it's suited for enclosed distribution panels, not washdown environments. Two plug-in slots accept auxiliary switch OF modules; one slot for an alarm switch SD; one slot for a voltage release MN or MX. That gives you remote status and shunt-trip capability without drilling the panel. The green trip indicator on the front gives local visual confirmation of a fault trip.

Carries UL 489, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 marks. CE marked. HACR rated for heating, air conditioning, and refrigeration applications.

MPN
MGP26500