Schneider Electric MGP26500 — 2-Pole MCB (DIN Rail)

MGP26500 PowerPact M Circuit Breaker, 500 A, 2-Pole, ET 1.0

MPNMGP26500
Obsolete

Schneider Electric PowerPact M, MGP26500, 2-pole 500 A circuit breaker, electronic ET 1.0 trip unit, 65 kAIC at 240 V AC, unit mount lug terminals, black.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP26500 — Identification
ParameterValue
Product namePowerPact M
Series / familyPowerPact
Product / component typeCircuit breaker
Device applicationDistribution
MGP26500 — Electrical
ParameterValue
Number of poles2P
Rated operational voltage [Ue]600 V AC 50/60 Hz UL 489
Network frequency50/60 Hz
MGP26500 — Protection
ParameterValue
Breaking capacity (Icu)AIR 65 kA 240 V AC 50/60 Hz UL 489 AIR 35 kA 480 V AC 50/60 Hz UL 489 AIR 18 kA 600 V AC 50/60 Hz UL 489 Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Rated service breaking capacity [Ics]25 kA 240 V AC 50/60 Hz IEC 60947-2 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Suitable for isolationYes IEC 60947-2
Trip unit technologyElectronic, basic, ET 1.0,
Operating / control typeOperating handle
MGP26500 — Mechanical
ParameterValue
Width8.27 in (210.06 mm)
Height12.86 in (326.64 mm)
Depth8.05 in (204.47 mm)
Mounting supportLug
Mounting modeUnit mount lug)
Terminal tightening torque442.5 lbf.in (50 N.m) 0.1...0.4 in² (95...240 mm²) (3 x AWG 3/0...3 x 500 kcmil)
Local signalling / indication1 trip indicator green)
MGP26500 — Environmental
ParameterValue
Operating temperature range-13...158 °F (-25...70 °C)
Storage temperature range-58...185 °F (-50...85 °C)
MGP26500 — Approvals
ParameterValue
Standards / complianceUL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2

Product details

The MGP26500 is a 500 A, 2-pole PowerPact M circuit breaker with an electronic ET 1.0 trip unit. The 65 kA AIR at 240 V AC (UL 489) and 35 kA at 480 V AC tell you it can handle high-fault-current panels without cascading upstream — critical for a main or large feeder in a distribution board. The IEC 60947-2 Icu of 50 kA at 240 V and 35 kA at 380/415 V means the same breaker meets both North American and international specs, so it fits a global BOM without a variant swap. The 80 % continuous current rating means the breaker is listed to carry 400 A continuously in a panel — not the full 500 A — unless you account for the 100 % rating option. That 80 % figure is the default for most UL 489 molded-case breakers; if your load pulls the full 500 A steady, you need to check the continuous-current derating for your enclosure and ambient.

This is a unit-mount breaker with lug terminals on line and load. The lug range accepts 3 x AWG 3/0 up to 3 x 500 kcmil aluminium or copper — sized for the 500 A feed. Tightening torque is 50 N·m (442.5 lbf·in) for the main conductors. Strip length is 25 mm (1.0 in). The IP40 front panel protection means it's suited for enclosed distribution panels, not washdown environments. Two plug-in slots accept auxiliary switch OF modules; one slot for an alarm switch SD; one slot for a voltage release MN or MX. That gives you remote status and shunt-trip capability without drilling the panel. The green trip indicator on the front gives local visual confirmation of a fault trip.

Carries UL 489, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 marks. CE marked. HACR rated for heating, air conditioning, and refrigeration applications.

Frequently asked questions

What is the breaking capacity of MGP26500?

The MGP26500 has a UL 489 AIR of 65 kA at 240 V AC, 35 kA at 480 V AC, and 18 kA at 600 V AC. IEC 60947-2 Icu is 50 kA at 240 V and 35 kA at 380/415 V.

What wire sizes does MGP26500 accept?

The lugs accept 3 x AWG 3/0 up to 3 x 500 kcmil aluminium or copper. Strip length is 25 mm (1.0 in).

MPN