Skip to main content
Schneider Electric SR2E121BD

Schneider SR2E121BD Zelio Logic Smart Relay, 24 V DC, 8 Inpu

MPN SR2E121BD
Active

Schneider Electric Zelio Logic compact smart relay SR2E121BD, 24 V DC, 8 discrete inputs, relay outputs, real-time clock with program memory integrity check on each power-up.

$63.50 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

SR2E121BD specifications
ParameterValue
Main product or component typeCompact smart relay
Response time10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-20 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61131-2
Mechanical life cycles10000000 cycles relay output
Backup time10 years 77 °F (25 °C)

Product details

It brings 8 discrete inputs per IEC 61131-2 Type 1 and relay outputs with a mechanical durability of 10 million cycles. A real-time clock is onboard, backed for 10 years at 77 °F (25 °C), and the unit checks program memory on each power-up — a detail that matters for unattended restarts or safety-related logic where memory corruption must be caught early.

Cycle time is 6...90 ms, setting the scan rate for ladder or FBD programs — typical for a smart relay, but if your application needs deterministic response below 10 ms, confirm the worst-case scan against your timing budget. Relay outputs switch at 0.1 Hz under load (Ie) and up to 10 Hz unloaded, with response times of 10 ms ON / 5 ms OFF. Off-state leakage and voltage state 0 guaranteed at 12 V / 10 mA; the current state 1 threshold is ≥ 15 V for the discrete input circuit. These are the numbers you need to match against your load switching profile. Clock drift is specified at 12 min/year over the full 32...131 °F range, or 6 s/month at 77 °F — acceptable for time-stamping and scheduling in most panel applications. Backup time of 10 years at 25 °C means the clock survives extended power-offs without external battery changes.

Compliance and environmental tolerances

Standards coverage includes IEC 61131-2 (Type 1 inputs, Zone B EMC), IEC 61000-6-2/3/4, and individual surge, burst, and radiated immunity tests at Level 3. Operating altitude 2000 m, IP40 front panel / IP20 terminals. These certifications align with the documentation a quality or safety engineer looks for when approving a smart relay for control panels.

MPN