Skip to main content
Schneider Electric VW3A46107A

Schneider VW3A46107A Passive Filter, 50 A, 380-480 V, 22 kW,

MPN VW3A46107A
Active

Schneider Electric Easy Altivar 610 passive filter, VW3A46107A, 50 A output, 380-480 V, 22 kW/30 hp, 50 Hz, THDI 10%, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VW3A46107A specifications
ParameterValue
Main product or component typePassive filter
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max45 °C
Temp operating min-25 °C
Storage temperature-25...85 °C storage in original packaging
Efficiency98%
Operating temperature-25...45 °C (without current derating)

Product details

Passive filter for ATV610 drives — 22 kW, 50 A output, THDI 10%

The VW3A46107A is a passive filter designed to pair with a Schneider ATV610 variable speed drive running a 22 kW / 30 hp motor on a 380-480 V three-phase line. It knocks input current harmonics down to 10 % THDI, which keeps the drive from rattling the rest of the panel's gear — especially important on shared transformers or generator-fed sites. The filter is rated for 32.5 A on the input side and 50 A on the output, so it handles the drive's full draw without choking. Efficiency sits at 98 %, with 327 W of thermal losses to vent. That's heat you need to account for in the enclosure — at full load it's about the same as a small space heater running inside the cabinet. Mounting is IP20, so it's meant for a clean, dry panel environment, not out in the washdown zone.

The 10 % THDI figure is what matters most here. Without a line filter, a standard VFD can push higher THDI back onto the line, tripping nuisance breakers or overheating transformers upstream. This filter brings that down to 10 %, which is clean enough to meet most plant power-quality specs without going to a full active front end. The UL 61800-5-1 and IEC 61800-5-1 certifications mean it's tested as part of a drive system for both safety and harmonic limits — not just a standalone choke. The 50 A output rating matches the drive's nominal current for a 22 kW motor at 400 V. The input rating of 32.5 A reflects the lower current draw on the line side after the filter's inductive stage. Connection terminals accept up to 10 mm² on the power lines and 2.5 mm² for the DC bus links — solid for the wire sizes you'd run on a 22 kW drive.

MPN
VW3A46107A