Skip to main content
Schneider Electric XUB2BPBNL2R

XUB2BPBNL2R Photoelectric Sensor, 15 m Range, PNP NC, IP67

MPN XUB2BPBNL2R

Schneider Electric XUB2BPBNL2R, 18 mm tubular through-beam photoelectric receiver, PNP normally-closed output, 15 m sensing range, 12-24 VDC, IP67, 2 m PVC cable, nickel-plated brass.

$72.09 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

XUB2BPBNL2R specifications
ParameterValue
Voltage12 TO 24 VDC
Response time1 MILLISECOND (ON/OFF)
Sensing distance15 M
MaterialNickel Plated Brass
Sensing positionFront

Product details

15 m through-beam receiver for long-range detection

The XUB2BPBNL2R is a tubular through-beam photoelectric receiver from the Schneider Electric XUB series, designed to work with a separate emitter to create a 15 m sensing beam. This range suits applications like conveyor belt monitoring, automated warehouse aisle detection, or long-distance object presence verification where a single housing won't fit both emitter and receiver. The 1 ms response time (on/off) means it can detect objects moving at line speed without missing pulses — a 15 m beam at 1 ms gives the downstream PLC enough time to react before the next part arrives.

IP67 brass barrel for washdown and outdoor duty

Rated IP67 and NEMA 4X/12, the nickel-plated brass housing withstands hose-down cleaning, condensation, and dust ingress common in food processing, beverage lines, or outdoor material handling. The threaded 18 mm barrel mounts through a standard bracket or drilled hole with the included nut. The 2 m PVC cable exits the rear — plan cable routing to avoid sharp bends at the gland entry, as the cable is the wet-end barrier, not the housing thread.

PNP NC output and switching behaviour

Output is PNP normally-closed (NC), meaning the signal line is high when the beam is uninterrupted and goes low when the beam is broken. This fail-safe configuration is standard for safety-related presence detection — a broken wire or power loss reads as a blocked beam. Maximum load current is 100 mA at 12-24 VDC, sufficient to drive a PLC input module directly without an interposing relay. The 500 Hz switching frequency supports fast counting applications up to 500 objects per second, provided the beam break duration exceeds the 1 ms response time.

Current lifecycle and sourcing posture

No direct stock-holding claim; quoted per order.

MPN
XUB2BPBNL2R