Skip to main content
Schneider Electric XUB2BPBNL2R — Photoelectric Sensors

XUB2BPBNL2R Photoelectric Sensor, 15 m Range, PNP NC, IP67

MPNXUB2BPBNL2R

Schneider Electric XUB2BPBNL2R, 18 mm tubular through-beam photoelectric receiver, PNP normally-closed output, 15 m sensing range, 12-24 VDC, IP67, 2 m PVC cable, nickel-plated brass.

$72.09Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XUB2BPBNL2R — Identification
ParameterValue
ModelXUB
XUB2BPBNL2R — Sensing
ParameterValue
Sensing distance15 M
Response time1 MILLISECOND (ON/OFF)
XUB2BPBNL2R — Electrical
ParameterValue
Operating voltage range12 TO 24 VDC
XUB2BPBNL2R — Connection
ParameterValue
Connection type2 M PVR CABLE
XUB2BPBNL2R — Environmental
ParameterValue
EnclosureNEMA 4X/12, IP67
XUB2BPBNL2R — Mechanical
ParameterValue
MaterialNICKEL PLATED BRASS

Product details

15 m through-beam receiver for long-range detection

The XUB2BPBNL2R is a tubular through-beam photoelectric receiver from the Schneider Electric XUB series, designed to work with a separate emitter to create a 15 m sensing beam. This range suits applications like conveyor belt monitoring, automated warehouse aisle detection, or long-distance object presence verification where a single housing won't fit both emitter and receiver. The 1 ms response time (on/off) means it can detect objects moving at line speed without missing pulses — a 15 m beam at 1 ms gives the downstream PLC enough time to react before the next part arrives.

IP67 brass barrel for washdown and outdoor duty

Rated IP67 and NEMA 4X/12, the nickel-plated brass housing withstands hose-down cleaning, condensation, and dust ingress common in food processing, beverage lines, or outdoor material handling. The threaded 18 mm barrel mounts through a standard bracket or drilled hole with the included nut. The 2 m PVC cable exits the rear — plan cable routing to avoid sharp bends at the gland entry, as the cable is the wet-end barrier, not the housing thread.

PNP NC output and switching behaviour

Output is PNP normally-closed (NC), meaning the signal line is high when the beam is uninterrupted and goes low when the beam is broken. This fail-safe configuration is standard for safety-related presence detection — a broken wire or power loss reads as a blocked beam. Maximum load current is 100 mA at 12-24 VDC, sufficient to drive a PLC input module directly without an interposing relay. The 500 Hz switching frequency supports fast counting applications up to 500 objects per second, provided the beam break duration exceeds the 1 ms response time.

Current lifecycle and sourcing posture

No direct stock-holding claim; quoted per order.

Frequently asked questions

What is the sensing range and output type of XUB2BPBNL2R?

The through-beam receiver has a 15 m sensing distance when paired with the matching emitter. Output is PNP normally-closed (NC), rated 100 mA maximum load at 12-24 VDC, with a 1 ms response time.

MPN