Schneider Electric A9D14820

Schneider Electric A9D14820 Acti9 iC60 RCBO, 20 A, 10 kA, 30

MPN A9D14820
Active

Schneider Electric Acti9 iC60 RCBO, A9D14820, 1P+N, 20 A rated current at 50 °C, 10 kA breaking capacity at 240 V AC, 30 mA earth-leakage sensitivity, curve C, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D14820 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230/240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IEC 61009-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-15 °C
Storage temperature-40...85 °C
ColorWhite
Depth77.5 mm
Width18 mm
Height110 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
Operating temperature-15...60 °C

Product details

It protects a 1P+N circuit at 20 A rated current (at 50 °C) with a 10 kA breaking capacity at 240 V AC, and integrates 30 mA earth-leakage protection. The curve C trip characteristic handles moderate inrush from motor or lighting loads without nuisance tripping.

The 10 kA Icn at 240 V AC (per IEC 61009-1) is the short-circuit breaking capacity this RCBO can safely interrupt. For a final sub-distribution board fed by a transformer with a prospective fault current under 10 kA, this unit clears faults without needing an upstream current-limiting device. The 30 mA earth-leakage sensitivity is the standard threshold for personal protection against indirect contact in TN earthing systems — it trips within 300 ms at 150 mA residual current, meeting IEC 61009-2-2 requirements. The thermal-magnetic trip unit gives two protection curves: the thermal element handles overloads (sustained overcurrents), while the magnetic element reacts to short-circuits. Curve C means the magnetic trip activates at 5 to 10 times In (100 to 200 A for this 20 A unit), which suits general-purpose circuits feeding socket outlets, lighting, and small motor loads.

Neutral on the left, outgoing on the bottom. The IP20 body is suitable for enclosed distribution boards; IP40 with modular enclosure.

MPN