Schneider Electric A9D14820 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D14820 Acti9 iC60 RCBO, 20 A, 10 kA, 30

MPNA9D14820
Active

Schneider Electric Acti9 iC60 RCBO, A9D14820, 1P+N, 20 A rated current at 50 °C, 10 kA breaking capacity at 240 V AC, 30 mA earth-leakage sensitivity, curve C, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D14820 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D14820 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D14820 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D14820 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D14820 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D14820 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

It protects a 1P+N circuit at 20 A rated current (at 50 °C) with a 10 kA breaking capacity at 240 V AC, and integrates 30 mA earth-leakage protection. The curve C trip characteristic handles moderate inrush from motor or lighting loads without nuisance tripping.

The 10 kA Icn at 240 V AC (per IEC 61009-1) is the short-circuit breaking capacity this RCBO can safely interrupt. For a final sub-distribution board fed by a transformer with a prospective fault current under 10 kA, this unit clears faults without needing an upstream current-limiting device. The 30 mA earth-leakage sensitivity is the standard threshold for personal protection against indirect contact in TN earthing systems — it trips within 300 ms at 150 mA residual current, meeting IEC 61009-2-2 requirements. The thermal-magnetic trip unit gives two protection curves: the thermal element handles overloads (sustained overcurrents), while the magnetic element reacts to short-circuits. Curve C means the magnetic trip activates at 5 to 10 times In (100 to 200 A for this 20 A unit), which suits general-purpose circuits feeding socket outlets, lighting, and small motor loads.

Neutral on the left, outgoing on the bottom. The IP20 body is suitable for enclosed distribution boards; IP40 with modular enclosure.

Frequently asked questions

Where can I buy the A9D14820 RCBO?

The A9D14820 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote.

What is the breaking capacity of the A9D14820?

The A9D14820 has a breaking capacity of 10,000 A Icn at 240 V AC, 50/60 Hz, conforming to IEC 61009-1.

What earth-leakage sensitivity does the A9D14820 provide?

The integrated earth-leakage protection is rated at 30 mA sensitivity, suitable for personal protection in TN earthing systems.

MPN