Schneider Electric A9F03202

Schneider Electric A9F03202 Acti9 iC60N MCB, 2 A, Curve B, 2

MPN A9F03202
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F03202, 2 A, B-curve, 2-pole, 50 kA Icu at 220-240 V AC, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03202 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03202 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The 2-pole (2P) configuration switches both line and neutral, giving full isolation on single-phase AC or DC circuits. Breaking capacity is the headline number here: 50 kA Icu at 220-240 V AC (per EN/IEC 60947-2) means this breaker can safely interrupt a fault current up to 50,000 A without welding its contacts or failing catastrophically. At 400 V AC the Icu drops to 25 kA, and under the domestic standard EN/IEC 60898-1 it's rated 6 kA Icn at 400 V — so for a commercial or industrial panel fed by a transformer with high prospective fault current, the 60947-2 rating is the one that governs coordination. Thermal-magnetic trip technology combines a bimetal strip for overload protection (time-delayed, inversely proportional to current) and a solenoid for short-circuit protection (instantaneous above the magnetic threshold).

Width is 36 mm (4 x 9 mm pitches), height 91 mm, depth 78.5 mm — fits a standard distribution board or sub-panel enclosure. The double-terminal design (top or bottom) allows daisy-chaining or looping the supply without additional distribution blocks. Local trip indicator and contact position indicator give visual confirmation of state without needing to meter the load side — useful during commissioning or fault-finding when the panel door is open.

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar) — this gives flexibility in specification: the same breaker can be used in a residential consumer unit (60898-1) or an industrial panel (60947-2), with the higher breaking capacity of the latter standard governing the fault rating. Relative humidity tolerance is 95 % at 55 °C. Suitability for isolation is confirmed under both standards — the breaker can be used as a disconnecting means for safe maintenance, provided the load side is de-energised and the toggle is padlockable (check the specific padlock accessory for this frame).