Skip to main content
Schneider Electric A9F03406

Schneider Electric A9F03406 Acti9 iC60N MCB, 6 A, 4P, B-Curv

MPN A9F03406
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 4P, 6 A, B-curve, 36 kA breaking capacity at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03406 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03406 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03406 is an Acti9 iC60N miniature circuit breaker rated at 6 A with 4 protected poles and a B-curve trip characteristic. It's a current-production part, so no lifecycle concerns for a new BOM line. Breaking capacity runs 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V AC per EN/IEC 60947-2. The Icn per EN/IEC 60898-1 is 10 kA at 400 V. The B-curve magnetic trip is 4 x In ±20 %. That's a lighting or resistive-load curve — not for motor starting.

Snaps onto DIN rail, 72 mm wide (8 x 9 mm pitches), 91 mm tall, 78.5 mm deep. That depth is the body only — allow clearance for the toggle throw and outgoing cable bend in a shallow enclosure. Double terminals top and bottom accept 1-25 mm² rigid or 1-16 mm² flexible. The IP20 finger-safe front is standard for enclosed distribution boards; it's not rated for wet locations.

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar). Pollution degree 3, overvoltage category IV, suitability for isolation marked on the device. That's the standard for non-condensing high-humidity environments — fine for most indoor plant rooms but not for direct washdown.

MPN
A9F03406