Skip to main content
Schneider Electric A9F03406 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F03406 Acti9 iC60N MCB, 6 A, 4P, B-Curv

MPNA9F03406
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 4P, 6 A, B-curve, 36 kA breaking capacity at 12-133 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F03406 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F03406 — Ratings
ParameterValue
Rated current (In)6 A
Poles configuration4P
Number of protected poles4
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F03406 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F03406 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F03406 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F03406 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F03406 is an Acti9 iC60N miniature circuit breaker rated at 6 A with 4 protected poles and a B-curve trip characteristic. It's a current-production part, so no lifecycle concerns for a new BOM line. Breaking capacity runs 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V AC per EN/IEC 60947-2. The Icn per EN/IEC 60898-1 is 10 kA at 400 V. The B-curve magnetic trip is 4 x In ±20 %. That's a lighting or resistive-load curve — not for motor starting.

Snaps onto DIN rail, 72 mm wide (8 x 9 mm pitches), 91 mm tall, 78.5 mm deep. That depth is the body only — allow clearance for the toggle throw and outgoing cable bend in a shallow enclosure. Double terminals top and bottom accept 1-25 mm² rigid or 1-16 mm² flexible. The IP20 finger-safe front is standard for enclosed distribution boards; it's not rated for wet locations.

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar). Pollution degree 3, overvoltage category IV, suitability for isolation marked on the device. That's the standard for non-condensing high-humidity environments — fine for most indoor plant rooms but not for direct washdown.

Frequently asked questions

What is the breaking capacity of A9F03406 at 400 V?

At 400 V AC the Icn per EN/IEC 60898-1 is 10 kA, and the Icu per EN/IEC 60947-2 is 10 kA at 380-415 V. For coordination work, use the 10 kA figure at 400 V.

MPN
A9F03406