Skip to main content
Schneider Electric A9F05132

Schneider Electric A9F05132 Acti9 iC60N MCB, 32 A, 1P, D Cur

MPN A9F05132
Active

Schneider Electric Acti9 iC60N, A9F05132, miniature circuit breaker, 1-pole, 32 A, D curve, 36 kA breaking capacity at 12-60 VAC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05132 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05132 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Breaking capacity reaches 36 kA Icu at 12-60 VAC (per EN/IEC 60947-2), which covers most industrial control panel fault levels. At 220-240 VAC the rating drops to 10 kA Icu, still adequate for standard distribution boards. The part carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (residential/commercial), giving you flexibility to spec it across plant and facility applications under one catalog number.

The 18 mm width per pole keeps panel density predictable. IP20 finger-safe front protects operators in open-panel environments. Rated insulation voltage is 500 VAC, overvoltage category IV, pollution degree 3 — suited for main distribution panels where transient overvoltages are a concern. Thermal-magnetic trip unit with a trip indicator provides local visual confirmation of a faulted circuit. Contact position indicator confirms the main contacts are open — useful during lockout/tagout verification. The part is suitability-for-isolation certified per both EN/IEC 60898-1 and EN/IEC 60947-2, meaning it can be used as a disconnecting means where local codes require it.

MPN
A9F05132