Skip to main content
Schneider Electric A9F05432

Schneider Electric A9F05432 Acti9 iC60N MCB, 32A, D Curve, 4

MPN A9F05432
Active

Schneider Electric Acti9 iC60N, A9F05432, miniature circuit breaker, 4P, 32 A, D curve, 36 kA breaking capacity, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05432 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F05432 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05432 is a 4-pole Acti9 iC60N miniature circuit breaker rated at 32 A with a D tripping curve. It uses thermal-magnetic trip technology for distribution applications, protecting against overloads and short circuits.

This MCB is certified to both EN/IEC 60898-1 and EN/IEC 60947-2, giving you flexibility in specifying it for residential, commercial, or industrial panels. The breaking capacity hits 36 kA Icu at 12-133 V AC, 20 kA Icu at 220-240 V AC, 10 kA Icu at 380-415 V AC, and 6 kA Icu at 440 V AC per the 60947-2 standard. Under the 60898-1 standard, it is rated for 10 kA Icn at 400 V AC. The high 36 kA rating at lower voltages means it can handle high-fault scenarios common in industrial control panels fed by large transformers.

Snaps onto a DIN rail (mounting support: DIN rail). Occupies 8 x 9 mm pitches (72 mm wide), with a depth of 78.5 mm and height of 91 mm. The double terminals on top and bottom accept 1-35 mm² rigid or 1-25 mm² flexible cable. The IP20 finger-safe front is standard for enclosed panels. Suitable for isolation per both EN/IEC 60898-1 and EN/IEC 60947-2, with a visible contact position indicator and a trip indicator for local signalling.

MPN
A9F05432