A9F06225 Acti9 iC60H MCB, 25 A, 2P, Curve B, 42 kA Icu

MPN A9F06225
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 25 A, 2P, curve B, 42 kA Icu at 12-133 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06225 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06225 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06225 is a 25 A, 2-pole miniature circuit breaker from the Acti9 iC60H series, curve B. The B-curve trips magnetically at 4 x In (±20%), so it clears short-circuit faults quickly but tolerates modest inrush — suited for resistive or general-purpose distribution loads, not motor starting. The 42 kA Icu at 12-133 V AC (EN/IEC 60947-2) is the maximum interrupting capacity the breaker can safely clear once; at 220-240 V AC it still holds 30 kA, and at 380-415 V AC it delivers 15 kA. The thermal-magnetic trip unit combines a bimetal for overload protection and a solenoid for short-circuit response. Mounts on a standard DIN rail (35 mm per EN 60715) and occupies 4 x 9 mm pitches — 36 mm wide. IP20 finger-safe terminals are standard for enclosed panel use.

Suitability for isolation is confirmed under both standards — the contact position indicator shows the true state of the contacts.