Specifications

A9F06225 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F06225 — Electrical
ParameterValue
Rated current [In]25 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9F06225 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F06225 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F06225 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F06225 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F06225 is a 25 A, 2-pole miniature circuit breaker from the Acti9 iC60H series, curve B. The B-curve trips magnetically at 4 x In (±20%), so it clears short-circuit faults quickly but tolerates modest inrush — suited for resistive or general-purpose distribution loads, not motor starting. The 42 kA Icu at 12-133 V AC (EN/IEC 60947-2) is the maximum interrupting capacity the breaker can safely clear once; at 220-240 V AC it still holds 30 kA, and at 380-415 V AC it delivers 15 kA. The thermal-magnetic trip unit combines a bimetal for overload protection and a solenoid for short-circuit response. Mounts on a standard DIN rail (35 mm per EN 60715) and occupies 4 x 9 mm pitches — 36 mm wide. IP20 finger-safe terminals are standard for enclosed panel use.

Suitability for isolation is confirmed under both standards — the contact position indicator shows the true state of the contacts.

Frequently asked questions

How do I get current pricing and availability for A9F06225?

Submit an RFQ against this order code. Pricing and stock are confirmed at quote time through independent distribution channels.

What is A9F06225's breaking capacity at 400 V?

At 380-415 V AC the Icu is 15 kA per EN/IEC 60947-2, and the Icn at 400 V per EN/IEC 60898-1 is 10 kA.

What compliance documentation does this brand provide for A9F06225?

The breaker carries dual certification to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1. RoHS and REACH declarations are standard for the Acti9 range.