Skip to main content
Schneider Electric A9F07132

Schneider Electric A9F07132 Acti9 iC60H MCB, 32 A, 1P, C-Cur

MPN A9F07132
Active

Schneider Electric Acti9 iC60H, A9F07132, 1P, 32 A, C-curve, 42 kA Icu at 12-60 V AC, thermal-magnetic miniature circuit breaker.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07132 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07132 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F07132 is a 1-pole Acti9 iC60H miniature circuit breaker rated 32 A with a C-curve magnetic trip (8 x In +/- 20 %). The C-curve means it tolerates moderate inrush — typical for lighting, small motor, and general distribution loads — without nuisance tripping. The 42 kA Icu at 12-60 V AC (EN/IEC 60947-2) gives headroom for high-fault installations; at 230 V AC the Icn is 10 kA per EN/IEC 60898-1, which covers standard domestic and light commercial panel duty. Dual-rated to both the distribution standard (60898-1) and the industrial standard (60947-2), so it qualifies for either spec line without a separate part number.

Deployment context

Snaps onto DIN rail (EN 60715) — 18 mm per pole, so this 1P unit occupies 2 x 9 mm pitches. The IP20 finger-safe terminals accept up to 35 mm² rigid or 25 mm² flexible wire; torque to 3.5 N·m. The toggle handle and trip-indicator flag give local status without opening the panel door.

MPN