Skip to main content
Schneider Electric A9F07410

A9F07410 Acti9 iC60H MCB, 4P C-curve 10 A, 42 kA

MPN A9F07410
Active

Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F07410, 4P, C-curve, 10 A, 42 kA Icu at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07410 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07410 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F07410 is a 4-pole miniature circuit-breaker from the Acti9 iC60H family, rated 10 A with a C-curve trip characteristic. It's built for distribution panels where you need overcurrent protection on a 4-wire (3-phase + neutral) circuit. Breaking capacity is the headline: 42 kA Icu at 12-133 V AC, 30 kA at 220-240 V, 15 kA at 380-415 V, and 10 kA at 440 V (all per EN/IEC 60947-2). That's a high-interrupting rating for a 10 A MCB — it can clear a fault on a strong transformer-fed bus without welding its contacts. The 15 kA Icn at 400 V per EN/IEC 60898-1 is the standard domestic/commercial rating, but the 60947-2 figures give you the industrial SCCR headroom for panel coordination studies.

Snaps onto a DIN rail (mounting support: DIN rail per). It takes 8 modules of 9 mm pitch (72 mm wide), so plan your enclosure rail space accordingly — that's a 4-pole breaker in a standard 72 mm footprint. Height is 91 mm, depth 78.5 mm; the toggle and trip indicator are on the front face.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial). That means it qualifies as a circuit-breaker for isolation (suitability for isolation: yes per both standards). Pollution degree 3, overvoltage category IV — rated for the harsh electrical environment at the service entrance or main distribution board.

MPN
A9F07410