Skip to main content
Schneider Electric A9F07432

Schneider Electric A9F07432 Acti9 iC60H MCB, 32 A, 4P, C-Cur

MPN A9F07432
Active

Schneider Electric Acti9 iC60H, A9F07432, miniature circuit breaker, 4P, 32 A, C-curve, 15 kA Icn at 400 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07432 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07432 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07432 is an Acti9 iC60H miniature circuit breaker (MCB) rated 32 A with a C-curve magnetic trip at 8 x In ±20 % — meaning it holds through moderate inrush (motor start, capacitor bank) and trips fast on a hard short. Four poles (4P) switch all live conductors, so it suits three-phase plus neutral distribution in a panel. The 15 kA Icn at 400 V AC (EN/IEC 60898-1) and 15 kA Icu at 380–415 V AC (EN/IEC 60947-2) tell you it safely interrupts fault currents up to that level without welding contacts or cascading upstream — sized for commercial and light industrial sub-distribution boards where the prospective short-circuit current is known. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit — no electronic auxiliary power needed, which keeps the trip curve stable across temperature swings inside a warm enclosure.

Snaps onto a DIN rail (mounting support per). The 72 mm width (9 mm pitches × 8) means it occupies eight modular spaces in a distribution board — plan the rail layout accordingly. Double terminals top and bottom accept 1–35 mm² rigid or 1–25 mm² flexible; strip length 14 mm, tighten to 3.5 N·m. The toggle control provides local on/off switching with a trip indicator (red flag) that shows when the breaker has opened on fault — useful for a technician scanning a row of MCBs to find the tripped circuit without metering each one.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar) — the same breaker covers both installation standards, which simplifies procurement when a panel must meet both a local residential code and an industrial machinery directive.

MPN
A9F07432