Skip to main content
Schneider Electric A9F45404

Schneider Electric A9F45404 Acti9 iC60N MCB, D Curve, 4A, 4P

MPN A9F45404
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, D curve, 4 A, 4 poles, 50 kA Icu breaking capacity at 415 V AC, clip-on rail mount, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F45404 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F45404 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F45404 is an Acti9 iC60N miniature circuit breaker (MCB) with a D curve, rated 4 A, 4 poles, and a breaking capacity of 50 kA Icu at 415 V AC.

This MCB is dual-rated to EN/IEC 60898-1 (for household and similar installations) and EN/IEC 60947-2 (for industrial applications). At 440 V AC it still handles 25 kA Icu. For the 60898-1 rating, the Icn is 10 kA at 415 V. If your panel's prospective short-circuit current (PSCC) at the breaker's point of installation exceeds 10 kA, you must use the 60947-2 rating (Category A, meaning no intentional short-time delay). The 4 A rating on a D curve is a common choice for small motor circuits, solenoid valves, or control transformers where the inrush can be 8–12 times the full-load current.

The terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip length is 14 mm, tightening torque 2 N·m. The toggle control gives a clear on/off position, and the trip indicator shows whether the breaker has opened on fault. IP20 finger protection means it is safe for use inside an enclosed panel but not in wet or dusty environments. Padlockable for lockout/tagout procedures.

MPN
A9F45404