Skip to main content
Schneider Electric A9F45404 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F45404 Acti9 iC60N MCB, D Curve, 4A, 4P

MPNA9F45404
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, D curve, 4 A, 4 poles, 50 kA Icu breaking capacity at 415 V AC, clip-on rail mount, thermal-magnetic trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F45404 — Identification
ParameterValue
Product nameDisbo iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
A9F45404 — Ratings
ParameterValue
Rated current (In)4 A
Poles configuration4P
Number of protected poles4
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated operational voltage (Ue)12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC/DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
A9F45404 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F45404 — Mechanical
ParameterValue
Mounting supportRail
Mounting modeClip-on
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height85 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F45404 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F45404 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F45404 is an Acti9 iC60N miniature circuit breaker (MCB) with a D curve, rated 4 A, 4 poles, and a breaking capacity of 50 kA Icu at 415 V AC.

This MCB is dual-rated to EN/IEC 60898-1 (for household and similar installations) and EN/IEC 60947-2 (for industrial applications). At 440 V AC it still handles 25 kA Icu. For the 60898-1 rating, the Icn is 10 kA at 415 V. If your panel's prospective short-circuit current (PSCC) at the breaker's point of installation exceeds 10 kA, you must use the 60947-2 rating (Category A, meaning no intentional short-time delay). The 4 A rating on a D curve is a common choice for small motor circuits, solenoid valves, or control transformers where the inrush can be 8–12 times the full-load current.

The terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip length is 14 mm, tightening torque 2 N·m. The toggle control gives a clear on/off position, and the trip indicator shows whether the breaker has opened on fault. IP20 finger protection means it is safe for use inside an enclosed panel but not in wet or dusty environments. Padlockable for lockout/tagout procedures.

Frequently asked questions

What is the A9F45404 used for?

It is a 4 A, D-curve miniature circuit breaker for motor circuits, transformers, and other loads with high inrush current, rated for industrial panels per EN/IEC 60947-2 and for building installations per EN/IEC 60898-1.

What is the breaking capacity of the A9F45404?

50 kA Icu at 415 V AC under EN/IEC 60947-2, and 10 kA Icn at 415 V AC under EN/IEC 60898-1.

Where can I buy the A9F45404?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN