Schneider Electric A9K23210

Schneider Electric A9K23210 Acti9 iK60N MCB, 2P, B Curve, 10

MPN A9K23210
Obsolete

Schneider Electric Acti9 iK60N, A9K23210, miniature circuit breaker, 2P, B curve, 10 A rated, 6 kA breaking capacity at 400 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K23210 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K23210 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K23210 is a 2-pole miniature circuit breaker from the Acti9 iK60N series, rated 10 A at 30 °C with a B tripping curve (3–5 x In magnetic trip). Breaking capacity is 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1.

The B curve (magnetic trip between 3 and 5 times In) is the most sensitive standard curve — it trips on moderate overloads faster than C or D curves, making it the usual choice for resistive loads, lighting circuits, and general-purpose socket outlets where inrush is low. Rated 10 A at 30 °C ambient; the thermal-magnetic trip unit is temperature-sensitive, so derating applies above 30 °C — a panel running at 40 °C will see the continuous current capacity drop. The 2-pole configuration protects both phase and neutral (or two phases) in a single module width of 36 mm (4 x 9 mm pitches).

Tunnel-type terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper, with a strip length of 14 mm and a tightening torque of 2 N·m. The IP20 finger-safe front is standard for enclosed panels. The toggle provides local ON/OFF indication, and a padlocking device can be fitted for lockout/tagout during maintenance. No earth-leakage protection is integrated — this is a straight overcurrent and short-circuit device only.