Skip to main content
Schneider Electric A9K23210 — 2-Pole MCB (DIN Rail)

Schneider Electric A9K23210 Acti9 iK60N MCB, 2P, B Curve, 10

MPNA9K23210
Obsolete

Schneider Electric Acti9 iK60N, A9K23210, miniature circuit breaker, 2P, B curve, 10 A rated, 6 kA breaking capacity at 400 V AC, clip-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9K23210 — Identification
ParameterValue
Product nameActi9 iK60
Series / familyActi9
Device short nameiK60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9K23210 — Electrical
ParameterValue
Rated current [In]10 A at 30 °C
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC
Network frequency50/60 Hz
A9K23210 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9K23210 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth78.5 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorNo
A9K23210 — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...85 °C
A9K23210 — Approvals
ParameterValue
Standards / complianceEN/IEC 60898-1

Product details

The Schneider Electric A9K23210 is a 2-pole miniature circuit breaker from the Acti9 iK60N series, rated 10 A at 30 °C with a B tripping curve (3–5 x In magnetic trip). Breaking capacity is 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1.

The B curve (magnetic trip between 3 and 5 times In) is the most sensitive standard curve — it trips on moderate overloads faster than C or D curves, making it the usual choice for resistive loads, lighting circuits, and general-purpose socket outlets where inrush is low. Rated 10 A at 30 °C ambient; the thermal-magnetic trip unit is temperature-sensitive, so derating applies above 30 °C — a panel running at 40 °C will see the continuous current capacity drop. The 2-pole configuration protects both phase and neutral (or two phases) in a single module width of 36 mm (4 x 9 mm pitches).

Tunnel-type terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper, with a strip length of 14 mm and a tightening torque of 2 N·m. The IP20 finger-safe front is standard for enclosed panels. The toggle provides local ON/OFF indication, and a padlocking device can be fitted for lockout/tagout during maintenance. No earth-leakage protection is integrated — this is a straight overcurrent and short-circuit device only.

Frequently asked questions

What is the breaking capacity of the A9K23210?

The A9K23210 has a breaking capacity of 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1.

What does the B curve mean on this MCB?

The B curve means the magnetic trip operates between 3 and 5 times the rated current (In), making it the most sensitive standard curve — suited for resistive loads and lighting circuits with low inrush.

What is the rated current of the A9K23210?

The rated current is 10 A at 30 °C ambient temperature.

MPN