Skip to main content
Schneider Electric A9L40201

Schneider Electric A9L40201 Acti9 iPRD40r Type 2 SPD, 40 kA

MPN A9L40201
Active

Schneider Electric Acti9 iPRD40r Type 2 surge arrester, A9L40201, 2P, 350 V, 40 kA max discharge, with remote signalling, clip-on DIN rail mount.

$101.83 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9L40201 specifications
ParameterValue
Voltage230 V AC (+/- 10 %) at 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Storage temperature-40...85 °C
ColorWhite (RAL 9003)
Depth69 mm
Width36 mm
Height85 mm
ApplicationDistribution
Operating temperature-25...60 °C

Product details

It's a 2-pole, MOV-based arrester rated 230 V AC (+/- 10 %) at 50/60 Hz, with a maximum continuous operating voltage (Uc) of 350 V common mode on both L/PE and N/PE paths. The headline numbers: 40 kA maximum discharge current (Imax) and 15 kA nominal discharge current (In) per the Type 2 test sequence. That means it handles direct lightning-induced surges up to 40 kA once, and repeatedly clamps 15 kA surges without degrading — the rating that governs coordination with downstream equipment. Protection level (Up) is under 1.4 kV common mode, which keeps let-through voltage low enough for most downstream switchgear and electronics to ride through without damage.

Clip-on DIN rail mount, 36 mm wide (4 x 9 mm pitches). Tightening torque 2.5 N·m. That's a standard panel footprint; fits alongside a 2-pole MCB in a distribution board. Comes with remote signalling contacts (1 C/O, rated 0.25 A / 250 V AC) for a panel lamp or PLC input to flag a failed cartridge. The signalling circuit voltage matches standard control voltages. Relative humidity 5 to 95 %. IK03 impact rating per IEC 62262 — tough enough for panel handling but not for direct mechanical abuse.

Coordination and associated breakers

The iPRD40r is designed to be paired with an upstream overcurrent protective device. Schneider lists compatible breakers: iC60H (40 A, curve C, 15 kA Icu), iC60N (40 A, curve C, 10 kA), NG125H (40 A, curve C, 36 kA), NG125L (40 A, curve C, 50 kA), NG125N (40 A, curve C, 25 kA), or fuses gG 63 A (15 kA) and gG 80 A (50 kA). Pick the one that matches your system's fault level. Temporary overvoltage (TOV) withstand: 337 V L/N for 5 seconds (withstand), 1200 V N/PE for 200 ms (safe failure mode). That covers most utility switching events without blowing the cartridge prematurely.

MPN