Skip to main content
Schneider Electric A9N16201

Schneider Electric A9N16201 Acti9 xID RCCB, 25 A, 30 mA, 2P

MPN A9N16201
Active

Schneider Electric Acti9 xID RCCB, A9N16201, 2P, 25 A, 30 mA, Type AC, 230-240 V AC, 50 Hz, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N16201 specifications
ParameterValue
Control typeToggle
Voltage230...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
IP ratingIP20
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite
Depth75 mm
Width36 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles4000 cycles
Operating temperature-5...40 °C

Product details

The Schneider Electric A9N16201 is an Acti9 xID residual current circuit breaker (RCCB) — a 2-pole device rated for 25 A continuous current with 30 mA earth-leakage sensitivity. The 30 mA threshold is the standard for personal protection against fatal electric shock in residential and commercial final circuits.

Rated at 25 A (In) with a breaking capacity of 500 A per IEC 61008-1. The 30 mA sensitivity trips on leakage to ground, protecting personnel. Type AC covers sinusoidal residual currents — common for resistive and inductive loads without electronics. If the circuit feeds switched-mode power supplies, VFDs, or LED drivers that generate pulsed or DC fault currents, Type A or Type B RCCBs would be needed instead. The 2-pole (2P) configuration switches both phase and neutral. Rated insulation voltage (Ui) is 500 V AC, and the operational voltage range is 230-240 V AC — single-phase line-to-neutral supplies. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable. The tunnel-type terminals allow daisy-chaining or looping through. IP20 rated — install inside an enclosure rated for the environment.

Designed and tested to IEC 61008-1 and EN 61008-2-1 — the international and European standards for residual current operated circuit-breakers without integral overcurrent protection. The device is suitable for isolation (disconnector function) and has a contact position indicator showing ON, OFF, or fault trip. A padlocking device can lock it in the OFF position for safe maintenance.

MPN
A9N16201