Skip to main content
Schneider Electric A9N16201 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N16201 Acti9 xID RCCB, 25 A, 30 mA, 2P

MPNA9N16201
Active

Schneider Electric Acti9 xID RCCB, A9N16201, 2P, 25 A, 30 mA, Type AC, 230-240 V AC, 50 Hz, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16201 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16201 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16201 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16201 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth75 mm
A9N16201 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16201 — Approvals
ParameterValue
StandardsIEC 61008-2-1 EN 61008-2-1 EN/IEC 61008-1

Product details

The Schneider Electric A9N16201 is an Acti9 xID residual current circuit breaker (RCCB) — a 2-pole device rated for 25 A continuous current with 30 mA earth-leakage sensitivity. The 30 mA threshold is the standard for personal protection against fatal electric shock in residential and commercial final circuits.

Rated at 25 A (In) with a breaking capacity of 500 A per IEC 61008-1. The 30 mA sensitivity trips on leakage to ground, protecting personnel. Type AC covers sinusoidal residual currents — common for resistive and inductive loads without electronics. If the circuit feeds switched-mode power supplies, VFDs, or LED drivers that generate pulsed or DC fault currents, Type A or Type B RCCBs would be needed instead. The 2-pole (2P) configuration switches both phase and neutral. Rated insulation voltage (Ui) is 500 V AC, and the operational voltage range is 230-240 V AC — single-phase line-to-neutral supplies. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable. The tunnel-type terminals allow daisy-chaining or looping through. IP20 rated — install inside an enclosure rated for the environment.

Designed and tested to IEC 61008-1 and EN 61008-2-1 — the international and European standards for residual current operated circuit-breakers without integral overcurrent protection. The device is suitable for isolation (disconnector function) and has a contact position indicator showing ON, OFF, or fault trip. A padlocking device can lock it in the OFF position for safe maintenance.

Frequently asked questions

What is A9N16201 used for?

The A9N16201 is a residual current circuit breaker (RCCB) used for earth-leakage protection in single-phase 230-240 V AC circuits. It trips at 30 mA leakage to protect against electric shock, and is installed on DIN rails in distribution boards for residential, commercial, and light industrial final circuits.

What is the difference between Type AC and Type A RCCBs?

Type AC RCCBs (like this A9N16201) detect sinusoidal AC residual currents only. Type A RCCBs additionally detect pulsed DC residual currents, which are generated by electronics such as rectifiers, switching power supplies, and VFDs. For circuits with those loads, a Type A device is required to ensure the leakage is detected.

Where can I buy A9N16201 and how is it quoted?

The A9N16201 is sourced and quoted to order against an RFQ through independent industrial-automation distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
A9N16201