Schneider Electric Acti9 C120H miniature circuit breaker, A9N18413, 80 A rated, B-curve, 2-pole, 15 kA breaking capacity at 400 V AC, thermal-magnetic trip, clip-on 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18413 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-30 °C
Storage temperature-40...70 °C
Pollution degree3 conforming to IEC 60947-2

All specifications

A9N18413 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width54 mm
Height81 mm
Electrical life cycles5000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...60 °C

Product details

The Schneider Electric A9N18413 is an Acti9 C120H miniature circuit breaker (MCB) rated 80 A at 30 °C with a B-curve trip characteristic (magnetic tripping between 3 and 5 x In). The headline breaking capacity is 15 kA Icn at 400 V AC 50/60 Hz per EN/IEC 60898-1, with an Icu of 10 kA at 440 V AC and 30 kA at 220–240 V AC per EN/IEC 60947-2. This dual-standard rating means the breaker is certified for both residential (60898-1) and industrial (60947-2) fault-clearing requirements, giving the specifying engineer flexibility in panel design without swapping hardware.

Mounts via clip-on to 35 mm DIN rail — standard for panel and enclosure integration. The 54 mm width (9 mm pitch × 6) occupies six modular spaces, which is typical for a 2-pole 80 A MCB in the Acti9 range. Tunnel-type terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible conductors; wire strip length is 15 mm, tightening torque 3.5 N·m. IP20 finger-safe protection is suitable for enclosed panels.

Dual-certified to EN/IEC 60898-1 (MCB standard for household and similar installations) and EN/IEC 60947-2 (low-voltage switchgear and controlgear standard for industrial application). This dual certification is the key differentiator: the same breaker satisfies both a domestic distribution board spec and an industrial panel SCCR study. Electrical durability is 5,000 cycles (IEC 60947-2), mechanical durability 20,000 cycles. Earth-leakage protection requires a separate block (not integrated).