Schneider Electric A9N19650

Schneider Electric A9N19650 DPN Vigi RCBO, 4 A Type B, 30 mA

MPN A9N19650
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, Type AC, 1P+N, 4 A, B curve, 30 mA sensitivity, 6 kA Icn at 230 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19650 specifications
ParameterValue
Control typeToggle
Product typeType AC
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9N19650 is a DPN Vigi earth leakage circuit breaker from the Acti9 range, combining overcurrent and residual current protection in a single 1P+N module. Rated 4 A at 30 °C with a Type B tripping curve and 30 mA earth leakage sensitivity, it covers the common residential and light commercial distribution outgoer where both short-circuit and ground-fault protection are needed on a single pole.

The 6 kA Icn breaking capacity at 230 V AC (EN 61009) is the standard domestic and light commercial fault-interruption level across most of Europe and Asia — adequate for final subcircuits where the prospective short-circuit current stays under that threshold. The 4 A rating and B curve (magnetic trip 3–5 × In) suit lighting and general-purpose socket circuits with low inrush; a C curve would be needed for motor or transformer loads. The 30 mA residual sensitivity is the standard for personal protection against indirect contact (EN 61008/61009). For circuits with variable-speed drives, LED drivers, or EV chargers that generate non-sinusoidal leakage, a Type A or Type F RCD would be required.

Snaps onto DIN rail (EN 60715) and occupies 4 × 9 mm pitches — 36 mm wide. The 1P+N format switches the phase and switches the neutral without overcurrent protection on the neutral pole, which is standard for single-phase final circuits in many markets. Tunnel terminals accept up to 16 mm² rigid or 10 mm² flexible cable, enough for a 4 A outgoer with voltage drop margins.