Schneider Electric A9N19772 Acti9 DPN Vigi RCBO, 10 A, C-cur

MPN A9N19772
Active

Schneider Electric Acti9 DPN Vigi RCBO, 10 A, C-curve, 6 kA, 1P+N, DIN rail, IP20/IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19772 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity6000 A Icn at 220...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max70 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-30...70 °C
Pollution degree3

All specifications

A9N19772 additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The 6 kA breaking capacity (Icn at 220...240 V AC, 50/60 Hz, per EN/IEC 61009-2-1) covers the majority of residential and light commercial fault levels. Clip-on mounting to DIN rail, with a 77.5 mm depth that fits standard modular enclosures.

The C-curve (5...10 x In magnetic trip) means this RCBO is suited for circuits with moderate inrush — lighting, general-purpose sockets, small motor loads — where a B-curve would nuisance-trip but a D-curve would be too slow for fault clearance. The 6 kA breaking capacity at 230 V is the standard domestic/commercial rating; if your installation requires 10 kA or higher SCCR, step up to the Acti9 iC60 range. The 1P+N configuration switches the phase and monitors neutral current for earth-leakage detection, but does not switch the neutral — verify that your distribution scheme expects a switched phase only. The thermal-magnetic trip unit is non-interchangeable, so the 10 A rating is fixed at ordering.

Clip-on to DIN rail (EN 60715). Tunnel terminals top and bottom accept 0.75...16 mm² rigid or 0.33...10 mm² flexible (with or without ferrule); tighten to 2 N·m. Strip length 15 mm. Neutral is on the left. Pollution degree 3, overvoltage category III per IEC 60364, meaning it's rated for fixed installations with transient overvoltages up to 4 kV.