Skip to main content
Schneider Electric A9N1P16BGN

Schneider Electric A9N1P16BGN Acti9 xC60 MCB, 16 A, 1P, B Cu

MPN A9N1P16BGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P16BGN, 1P, 16 A, B-curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P16BGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N1P16BGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P16BGN is a 1-pole Acti9 xC60 miniature circuit breaker rated 16 A with a B-curve trip characteristic. It clips onto a 35 mm DIN rail and occupies 2 x 9 mm pitches (18 mm wide), making it a standard single-module fit for distribution boards. The 10 kA Icn breaking capacity at 240 V AC per IS/IEC 60898-1 covers most residential and light commercial fault levels.

The B-curve magnetic trip operates at 3 to 5 times In (48 to 80 A), so it's sized for resistive and general-purpose loads where inrush is modest — lighting circuits, socket outlets, small heaters. The thermal-magnetic trip unit handles overloads via a bimetal strip and shorts via a solenoid, a proven combination. Breaking capacity of 10 kA Icn at 240 V AC means this MCB can safely interrupt a fault current up to 10,000 A without welding contacts or failing catastrophically. The IP20 finger-safe terminals are standard for enclosed distribution boards.

Clip-on mounting to 35 mm DIN rail with tunnel-type terminals accepting up to 25 mm² rigid or 16 mm² flexible cable. Bottom connections only; wire strip length is 13 mm. The 77.5 mm depth is shallow enough for most 100 mm deep enclosures, though check gland-plate clearance if wiring from the rear. The ON/OFF toggle provides local contact position indication.

MPN
A9N1P16BGN