Schneider Electric A9N1P16BGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P16BGN Acti9 xC60 MCB, 16 A, 1P, B Cu

MPNA9N1P16BGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P16BGN, 1P, 16 A, B-curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P16BGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P16BGN — Electrical & Protection
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P16BGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P16BGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P16BGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P16BGN is a 1-pole Acti9 xC60 miniature circuit breaker rated 16 A with a B-curve trip characteristic. It clips onto a 35 mm DIN rail and occupies 2 x 9 mm pitches (18 mm wide), making it a standard single-module fit for distribution boards. The 10 kA Icn breaking capacity at 240 V AC per IS/IEC 60898-1 covers most residential and light commercial fault levels.

The B-curve magnetic trip operates at 3 to 5 times In (48 to 80 A), so it's sized for resistive and general-purpose loads where inrush is modest — lighting circuits, socket outlets, small heaters. The thermal-magnetic trip unit handles overloads via a bimetal strip and shorts via a solenoid, a proven combination. Breaking capacity of 10 kA Icn at 240 V AC means this MCB can safely interrupt a fault current up to 10,000 A without welding contacts or failing catastrophically. The IP20 finger-safe terminals are standard for enclosed distribution boards.

Clip-on mounting to 35 mm DIN rail with tunnel-type terminals accepting up to 25 mm² rigid or 16 mm² flexible cable. Bottom connections only; wire strip length is 13 mm. The 77.5 mm depth is shallow enough for most 100 mm deep enclosures, though check gland-plate clearance if wiring from the rear. The ON/OFF toggle provides local contact position indication.

Frequently asked questions

What is the breaking capacity of A9N1P16BGN?

10,000 A Icn at 240 V AC, 50/60 Hz, conforming to IS/IEC 60898-1.

What is the depth of A9N1P16BGN?

77.5 mm depth, 18 mm width (2 x 9 mm pitches), 85 mm height.

Where can I buy A9N1P16BGN?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability.

What standards does A9N1P16BGN comply with?

It complies with IS/IEC 60898-1 and includes tropicalisation level 2 per IEC 60068-1.

MPN