Skip to main content
Schneider Electric A9N1P16CIN

Schneider Electric A9N1P16CIN Acti9 xC60 MCB, 16 A, C-Curve,

MPN A9N1P16CIN
Active

Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N1P16CIN, 1-pole, 16 A rated, C-curve, 10 kA Icu at 240 V AC, clip-on 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P16CIN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C

All specifications

A9N1P16CIN additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P16CIN is a 1-pole miniature circuit-breaker from the Acti9 xC60 range, rated 16 A with a C-curve trip characteristic. It clips onto a standard 35 mm DIN rail and occupies 18 mm width — two 9 mm pitches — so it fits a compact panel layout.

Breaking capacity is 10 kA Icu at 220–240 V AC 50/60 Hz per IS/IEC 60947-2, which covers most commercial and light industrial distribution panels. At 12–48 V DC the rating rises to 15 kA Icu; at 60 V DC it drops to 6 kA Icu. The C-curve magnetic trip triggers at 8 x In ±20 % — 128 A nominal — so it handles moderate inrush from motor starters or lighting ballasts without nuisance tripping.

Termination and environmental

IP20 finger-safe protection is standard for enclosed panel use. Tropicalisation class 2 per IEC 60068-1 and 95 % relative humidity at 55 °C mean it holds up in warm, humid environments — think coastal or unconditioned electrical rooms.

MPN