Skip to main content
Schneider Electric A9N1P16CIN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P16CIN Acti9 xC60 MCB, 16 A, C-Curve,

MPNA9N1P16CIN
Active

Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N1P16CIN, 1-pole, 16 A rated, C-curve, 10 kA Icu at 240 V AC, clip-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P16CIN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P16CIN — Electrical & Protection
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P16CIN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P16CIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P16CIN — Approvals
ParameterValue
Conformity standardsIS/IEC 60947-2
A9N1P16CIN — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IS/IEC 60947-2
[Uimp] rated impulse withstand voltage4 kV conforming to IS/IEC 60947-2

Product details

The Schneider Electric A9N1P16CIN is a 1-pole miniature circuit-breaker from the Acti9 xC60 range, rated 16 A with a C-curve trip characteristic. It clips onto a standard 35 mm DIN rail and occupies 18 mm width — two 9 mm pitches — so it fits a compact panel layout.

Breaking capacity is 10 kA Icu at 220–240 V AC 50/60 Hz per IS/IEC 60947-2, which covers most commercial and light industrial distribution panels. At 12–48 V DC the rating rises to 15 kA Icu; at 60 V DC it drops to 6 kA Icu. The C-curve magnetic trip triggers at 8 x In ±20 % — 128 A nominal — so it handles moderate inrush from motor starters or lighting ballasts without nuisance tripping.

Termination and environmental

IP20 finger-safe protection is standard for enclosed panel use. Tropicalisation class 2 per IEC 60068-1 and 95 % relative humidity at 55 °C mean it holds up in warm, humid environments — think coastal or unconditioned electrical rooms.

Frequently asked questions

What are the key ratings of the A9N1P16CIN?

Rated current 16 A, C-curve, 1-pole, breaking capacity 10 kA Icu at 240 V AC per IS/IEC 60947-2, thermal-magnetic trip unit, suitable for isolation.

Where can I buy the A9N1P16CIN?

The A9N1P16CIN is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does the A9N1P16CIN comply with?

It complies with IS/IEC 60947-2 and carries tropicalisation class 2 per IEC 60068-1.

MPN
A9N1P16CIN