Skip to main content
Schneider Electric A9N26477

Schneider Electric A9N26477 Acti9 MX Shunt Trip, 48V AC/DC,

MPN A9N26477
Active

Schneider Electric Acti9 MX shunt trip release, 48 V AC/DC control voltage, 18 mm wide, 73.5 mm deep, EN/IEC 60947-2, obsolete.

$136.62 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N26477 specifications
ParameterValue
Main product or component typeShunt trip release
Coil voltage48 V AC 50/60 Hz 48 V DC
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
ColorWhite
Depth73.5 mm
Width18 mm
Height82.5 mm
Operating temperature-25...50 °C

Product details

It sits downstream of the breaker's trip mechanism; when you apply 48 V AC or DC to its control circuit, it mechanically trips the host breaker, giving you a remote emergency-stop or interlock function without running power wiring through the breaker itself. The control circuit draws its power from a separate source, not the breaker's load path. Mounts on a 35 mm symmetrical DIN rail, occupies 18 mm of panel width (one modular pitch), and the depth is 73.5 mm — standard for the Acti9 accessory footprint. The white housing carries a mechanical action indicator so you can see the trip state at a glance.

Lifecycle reality — obsolete, not gone

No official Schneider successor order code exists for this shunt trip variant.

The 48 V control voltage is the key fit parameter — it must match your trip-signal source. The part works on both AC and DC at that same voltage, which simplifies wiring in mixed-supply panels. The 18 mm width means it takes one standard DIN-rail pitch; if your panel is tight, that's one less modular slot than a two-pitch accessory. EN/IEC 60947-2 is the standard for low-voltage switchgear and controlgear — specifically the section covering circuit-breaker accessories. That certification tells you the shunt trip has been type-tested for coordination with the host breaker, so you don't lose selectivity or breaking capacity when you add it. The bottom screw-clamp terminals accept 0.5 to 2.5 mm² rigid or 1.5 mm² flexible (with or without ferrule), with a stripping length of 9 mm and a tightening torque of 1 N·m. That's standard for control wiring in a panel — no special tooling needed.

MPN
A9N26477