Schneider Electric A9N26612

Schneider Electric A9N26612 Vigi xC60 RCD Add-on, 2P 63A AC

MPN A9N26612
Active

Schneider Electric Acti9 Vigi xC60 add-on residual current device, A9N26612, 2P, 63 A, 100 mA, Type AC, instantaneous, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N26612 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...240 V conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
Depth74.5 mm
Width72 mm
Height87 mm
Operating temperature-5...60 °C

Product details

The Schneider Electric A9N26612 is a Vigi xC60 add-on residual current device (RCD) from the Acti9 range, designed to bolt onto the outgoing side of a compatible MCB via screw terminals. It is a 2-pole unit rated for 63 A continuous current with a 100 mA earth-leakage sensitivity, Type AC (sinusoidal AC residual currents only). The trip mechanism is electromechanical and voltage-independent — it clears a ground fault even if the phase voltage collapses, which matters for circuits where the neutral reference could be lost.

63 A at 230-240 V AC means this block handles the full current of a 63 A breaker downstream — no derating needed for the RCD itself at that load. The 100 mA sensitivity is less common than 30 mA; it is specified for circuits where nuisance tripping from normal leakage (long cable runs, heater elements, IT equipment) would be a problem, while still providing earth-fault protection. Type AC means it detects only sinusoidal AC residual currents — not pulsed DC or smooth DC — so it is not suitable for circuits with VFDs, UPS outputs, or EV chargers that generate DC fault currents.

Clip-on mounting to DIN rail, 4 modules wide (72 mm). The 74.5 mm depth fits standard Acti9 enclosures. Bottom tunnel terminals accept 1 to 35 mm² rigid or 1 to 25 mm² flexible cable; strip length 14 mm, tighten to 3.5 N·m. The red indicator on the front shows tripped status. IP20 on the body, IP40 inside a modular enclosure — fine for dry indoor panels, not for washdown areas.