Skip to main content
Schneider Electric A9TAA2225

A9TAA2225 Acti9 Active ARC iC60 25A 2P AFDD, 230V

MPN A9TAA2225
Active

Schneider Electric Acti9 Active ARC iC60, arc fault detection add-on block, 25 A, 2P, 230 V AC, clip-on DIN rail, EN/IEC 62606.

$395.87 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TAA2225 specifications
ParameterValue
Voltage230 V AC 50 Hz conforming to IEC 62606
Insulation voltage ui400 V AC 50 Hz
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to IEC 62606
ColorWhite (RAL 9003)
Depth73 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles 230 V AC conforming to IEC 62606
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...60 °C

Product details

The A9TAA2225 is an Acti9 Active ARC iC60 arc fault detection add-on block from Schneider Electric, rated 25 A at 230 V AC on a 50 Hz network. It clips onto the left side of an iC60 MCB (neutral left) and adds series arc-fault detection per EN/IEC 62606, plus overvoltage, earth leakage, and overload event management. The local LED signals ON, OFF, fault trip, and arc fault diagnostics — no need to pull a meter to see what tripped it.

The 25 A rated current (In) and 230 V operational voltage (Ue) define the load side: this block monitors the downstream circuit for arc faults and disconnects when it detects one. The 275 V threshold tripping voltage (+/- 5 V) means it catches sustained overvoltage events that could start a fire — not a transient spike, a genuine overvoltage condition. Accuracy on the measurement side is +/- 2 % for voltage and current, +/- 5 % for power, which is tight enough for energy monitoring via the EcoStruxure Panel Server concentrators (Advanced, Entry, or Universal). Electrical durability is 10,000 cycles at 230 V AC per IEC 62606; mechanical durability is 20,000 cycles. That means the arc fault detection electronics and the switching mechanism are rated for the full service life of a typical distribution board — the mechanical cycles outlast the electrical because arc-fault trips are infrequent. Clip-on mounting on DIN rail, 2 module pitches (9 mm each), so it occupies 18 mm of rail width. Terminal capacity is 1...10 mm² flexible or 1...16 mm² rigid, tunnel type, with a 2 N.m tightening torque and 14 mm wire strip length.

MPN
A9TAA2225