Skip to main content
Schneider Electric A9TPE4616

Schneider Electric A9TPE4616 Acti9 iC40 ARC, 16 A C-curve AF

MPN A9TPE4616
Active

Schneider Electric Acti9 iC40 ARC arc fault detection circuit breaker, 1P+N, 16 A, C-curve, 3 kA Icn / 10 kA Icu, DIN-rail clip-on, white (RAL 9003).

$256.82 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TPE4616 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC
Breaking capacity3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2

All specifications

A9TPE4616 additional specifications
ParameterValue
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...40 °C

Product details

Arc fault detection circuit breaker — 16 A, C-curve, 1P+N

Breaking capacity is 3 kA Icn per EN/IEC 60898-1 and 10 kA Icu per EN/IEC 60947-2 at 230 V AC 50 Hz — the Icu figure is the one that matters for coordination with an upstream MCCB in a panel. Limitation class 3 means it lets through less energy during a fault, helping downstream selectivity. Tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible, with a 2 N·m torque spec. IP20 finger-safe front, suitable for enclosed distribution boards.

Arc fault diagnostics and local signalling

Local signalling includes ON/OFF toggle position plus a fault-trip LED and a dedicated arc fault diagnostic LED — the arc fault LED distinguishes an arc event from a simple overcurrent trip, which saves troubleshooting time on a line-down call. The toggle is the control type; cable entry is top and bottom. Suitability for isolation is marked yes, and a contact position indicator is fitted — so the breaker can serve as a local disconnecting means for the outgoing circuit where regulations require visible isolation.

Tropicalisation severity B per IEC 60068-2-30 for 28 days means the internal components are tested against humidity cycling — relevant for installations in non-conditioned enclosures or coastal environments. Pollution degree 2 (non-conductive pollution only) is the standard for clean indoor panels. Electrical and mechanical durability are both rated 20 000 cycles — that is the operational life under load for the electromechanical mechanism, not the arc fault electronics which have no wear mechanism.

MPN
A9TPE4616