A9V31240 Acti9 Vigi iC60 RCBO, 2P 40A 30mA Type A-SI

MPN A9V31240
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V31240, 2P, 40 A rated current, 30 mA earth-leakage sensitivity, Type A-SI (Super Immunised), clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V31240 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...240 V AC 50/60 Hz conforming to EN 61009-1 230...240 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width72 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9V31240 is an Acti9 Vigi iC60 add-on residual current device — a 2-pole, 40 A, 30 mA unit with Type A-SI (Super Immunised) earth leakage protection. It clips onto a DIN rail alongside the matching iC60 MCB, forming a combined RCBO assembly for outgoing circuits in AC networks at 230...240 V, 50/60 Hz.

Type A-SI (Super Immunised) handles pulsed DC fault currents from electronics (VFDs, UPS, LED drivers) that would blind a standard Type A device, plus it resists nuisance tripping from transient surges up to 3 kA (8/20 µs waveform). Rated operational voltage is 230...240 V AC — this is a single-phase (line-to-neutral) device for 2-pole switching. The 40 A rated current matches the upstream MCB; the add-on block does not have its own overcurrent protection, so it must be paired with a 40 A iC60 breaker. Voltage-independent tripping means the RCD module does not need a separate power supply to detect leakage — it uses the fault energy itself. This makes it immune to neutral loss scenarios that can disable electronically-driven RCDs. IP20 on the body, IP40 inside the modular enclosure — suitable for dry indoor panel environments.

Clip-on mounting to DIN rail, 4 modules wide (9 mm pitch each = 36 mm total width). The 72 mm width, 91 mm height, and 73.5 mm depth fit standard Acti9 comb busbars on the bottom side. Tunnel terminals accept 1...35 mm² rigid or 1...25 mm² flexible conductors; tighten to 3.5 N·m. Strip 14 mm for bottom connection. The trip indicator gives local visual confirmation of RCD operation — useful during fault-finding without needing a test set.