Schneider Electric A9Y76740 Acti9 Vigi iCG40 RCD, 40A 300mA

MPN A9Y76740
Active

Schneider Electric Acti9 Vigi iCG40 add-on residual current device, 3P+N, 40 A rated, 300 mA sensitivity, Type A-SI super immunised, selective, voltage independent, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y76740 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width108 mm
Height99.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9Y76740 is an add-on residual current device (RCD) from the Acti9 Vigi iCG40 range, designed to bolt onto the outgoing side of a compatible Acti9 MCB via the screw terminals. It provides earth-leakage protection for a 3P+N circuit at 40 A rated current and 400 V AC operational voltage. The 300 mA sensitivity is selective (time-delayed), so it coordinates with downstream 30 mA RCDs — the upstream unit holds off during a fault to let the closer device clear first, avoiding a whole-section blackout for a single branch fault.

Rated at 40 A (In) and 400 V AC, this RCD handles the full load current of a typical sub-distribution board feeding lighting, general-purpose sockets, or small motor circuits — not a main incomer for a whole building, but a group feeder. The Type A-SI (Super Immunised) classification means it rejects nuisance tripping from pulsed DC fault currents and high-frequency leakage common in VFD-driven loads, switched-mode power supplies, and electronic ballasts. Standard Type A RCDs can false-trip on those waveforms; the A-SI variant holds steady. Voltage-independent tripping (no need for an auxiliary supply) means the RCD clears a ground fault even if the line voltage collapses — critical for safety in a group incomer where a lost neutral could otherwise leave a fault undetected.

Clip-on DIN rail mounting, 108 mm wide (6 x 9 mm pitches), with a depth of 74 mm and height of 99.5 mm. Tunnel-type terminals accept 1…16 mm² rigid or 1…10 mm² flexible cable on top; strip length 14 mm, tighten to 2 N·m. The screw connection to the upstream MCB uses the same terminals — no pigtail or flying leads. Rated for ambient operation from -25 °C to 60 °C, storage from -40 °C to 85 °C, and up to 2000 m altitude.

MPN
A9Y76740