Skip to main content
Schneider Electric C25R46E160

C25R46E160 ComPacT NSX 160A 4P MCCB, MicroLogic 6.2 E, 200 k

MPN C25R46E160
Active

Schneider Electric ComPacT NSX 250R frame, 160 A, 4-pole MCCB with MicroLogic 6.2 E electronic trip unit, 200 kA Icu at 415 V AC, LSIG protection, LCD display, toggle control.

$23.85 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25R46E160 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C

All specifications

C25R46E160 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C25R46E160 is a Schneider Electric ComPacT NSX 250R frame moulded-case circuit breaker, rated 160 A at 40 °C, with a MicroLogic 6.2 E electronic trip unit providing LSIG protection — overload (L), short-time short-circuit (S), instantaneous short-circuit (I), and ground fault (G). It is a 4-pole unit with front connections, a toggle control, and an LCD display for energy metering and event logs.

The 140 mm width, 161 mm height, and 86 mm depth fit standard ComPacT NSX cutouts. Operating altitude is 0–2000 m without derating; above that, derate per the manufacturer's curve.

The MicroLogic 6.2 E trip unit adds ground-fault protection (G) on top of the standard LSIG set, plus energy metering — demand current, power, power quality, time-stamped event tables. This distinguishes it from a basic thermal-magnetic breaker: you get adjustable protection curves, thermal memory (20 min before and after tripping), and communication of data for integration with a building management or SCADA system. The 20000-cycle mechanical durability and 10000-cycle electrical durability at 440 V In give a realistic service life for distribution duty.

MPN
C25R46E160