Schneider C60H1P6AD C60 MCB, 6 A, D Curve, 1 Pole, 15 kA

MPN C60H1P6AD
Obsolete

Schneider Electric C60H1P6AD, Multi9 C60H series, miniature circuit breaker, 1-pole, 6 A rated current, D curve, 15 kA breaking capacity at 230 V AC, thermal-magnetic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H1P6AD specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width18 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H1P6AD is a 1-pole thermal-magnetic miniature circuit breaker from the Multi9 C60 range, rated 6 A at 40 °C with a D tripping curve (10–14 × In magnetic trip limit). Breaking capacity is 15 kA Icu at 230–240 V AC (IEC 60947-2), with a service breaking capacity Ics of 15 kA at 12–440 V AC — meaning it can safely interrupt a fault up to 15 kA and still be usable afterward. At 400 V AC the Icu drops to 4 kA, so if your panel feeds a 400 V bus with a high prospective fault current, this breaker needs upstream current limitation or a higher-rated device. The 6 kV impulse withstand voltage (Uimp) covers typical transient overvoltages in distribution panels.

DIN rail integration and panel fit

Depth is 73 mm, height 81 mm — standard for the C60 family, so it drops into any Multi9 distribution board without a footprint conflict. The toggle switch provides local ON/OFF indication and a contact position indicator confirms isolation status — useful for lockout/tagout verification when the breaker is used as a disconnector (suitability for isolation per IEC 60947-2).