Skip to main content
Schneider Electric C60H1P6AD — 1-Pole MCB (DIN Rail)

Schneider C60H1P6AD C60 MCB, 6 A, D Curve, 1 Pole, 15 kA

MPNC60H1P6AD
Obsolete

Schneider Electric C60H1P6AD, Multi9 C60H series, miniature circuit breaker, 1-pole, 6 A rated current, D curve, 15 kA breaking capacity at 230 V AC, thermal-magnetic trip unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H1P6AD — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60H1P6AD — Electrical & Protection
ParameterValue
Rated current (In)6 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu / AIR)15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H1P6AD — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H1P6AD — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H1P6AD — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The C60H1P6AD is a 1-pole thermal-magnetic miniature circuit breaker from the Multi9 C60 range, rated 6 A at 40 °C with a D tripping curve (10–14 × In magnetic trip limit). Breaking capacity is 15 kA Icu at 230–240 V AC (IEC 60947-2), with a service breaking capacity Ics of 15 kA at 12–440 V AC — meaning it can safely interrupt a fault up to 15 kA and still be usable afterward. At 400 V AC the Icu drops to 4 kA, so if your panel feeds a 400 V bus with a high prospective fault current, this breaker needs upstream current limitation or a higher-rated device. The 6 kV impulse withstand voltage (Uimp) covers typical transient overvoltages in distribution panels.

DIN rail integration and panel fit

Depth is 73 mm, height 81 mm — standard for the C60 family, so it drops into any Multi9 distribution board without a footprint conflict. The toggle switch provides local ON/OFF indication and a contact position indicator confirms isolation status — useful for lockout/tagout verification when the breaker is used as a disconnector (suitability for isolation per IEC 60947-2).

Frequently asked questions

What is the C60H1P6AD used for?

It is a miniature circuit breaker for distribution applications, rated 6 A with a D curve, suited for protecting circuits with motor or transformer loads where high inrush current is expected. It mounts on a 35 mm DIN rail and occupies 2 module pitches.

What breaking capacity does the C60H1P6AD have?

The Icu is 15 kA at 230–240 V AC and 4 kA at 400–415 V AC, per IEC 60947-2. The Ics at 12–440 V AC is also 15 kA, meaning the breaker remains usable after clearing a fault at that level.

Where can I buy the C60H1P6AD?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
C60H1P6AD