Skip to main content
Schneider Electric C60H2P50AD

Schneider Electric C60H2P50AD MCB, 50 A, 2P, D Curve, 10 kA

MPN C60H2P50AD
Obsolete

Schneider Electric Multi9 C60H, miniature circuit breaker, C60H2P50AD, 2P, 50 A, D curve, 10 kA Icn at 230/400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H2P50AD specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width36 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H2P50AD is a 2-pole miniature circuit breaker from the Schneider Electric Multi9 C60H range, rated 50 A at 40 °C with a D tripping curve (magnetic trip 10–14 × In). Breaking capacity is 10 kA Icn per EN 60898 at 230/400 V AC, and under IEC 60947-2 the ultimate breaking capacity (Icu) reaches 15 kA at 400–415 V AC and 30 kA at 230–240 V AC. For a 50 A feeder in a typical commercial or light-industrial panel, 10 kA at the service entrance is adequate for most installations; the higher Icu figures confirm the breaker can clear a fault at the bus without welding contacts, even when the available fault current is higher than the Icn rating. The service breaking capacity (Ics) is 7.5 kA per EN 60898 at 230/400 V AC, meaning after clearing a fault at that level the breaker remains functional and can be reclosed — not just a one-shot device. This matters for selectivity studies: if the upstream device is a 63 A moulded-case breaker with a higher Icu, the C60H2P50AD can be coordinated to let the downstream MCB clear first.

Mounts on a 35 mm symmetrical DIN rail (EN 60715) and occupies 4 modules of 9 mm pitch — 36 mm total width. For panel builders, the 73 mm depth leaves clearance for standard 80 mm deep enclosures. The toggle handle provides local ON/OFF indication and a contact position indicator confirms the state of the moving contacts — useful for lockout/tagout verification during maintenance.

MPN
C60H2P50AD