Skip to main content
Schneider Electric ENW13266

Schneider ENW13266 EasyPact NW Switch Disconnector, 800 A, 3

MPN ENW13266
Active

Schneider Electric EasyPact NW series, ENW13266 switch disconnector, 3 poles, 800 A AC-23A, 440 V AC, drawout mounting, IP30.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW13266 specifications
ParameterValue
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-3
CurrentAC-23 A: 800 A AC 50/60 Hz 440 V
Utilization categoryAC-23 A
IP ratingIP30
Terminal pitch70 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth277 mm
Width288 mm
Height322 mm
ApplicationDistribution
Operating temperature-5...70 °C

Product details

What the 800 A AC-23A rating means for your distribution panel

The ENW13266 is a 3-pole switch disconnector from the EasyPact NW range, rated 800 A in AC-23A utilisation category at 440 V AC. For distribution duty where you need a visible-break isolator that also handles motor starting currents, this is the spec that confirms fit.

Drawout mounting and panel integration

Mounts on a rail base plate in drawout configuration — the switch body can be withdrawn from the base for inspection or replacement without disturbing the main power connections. Connection pitch is 70 mm without spreader, rear-connected, with both vertical and horizontal orientation allowed. Panel cutout dimensions: 322 mm height × 288 mm width × 277 mm depth.

Withstand and making capacity — what the short-circuit ratings protect

Rated short-time withstand current (Icw) is 50 kA for 1 second at 220–440 V — that's the fault current the switch can carry without damage while upstream protection clears. Rated short-circuit making capacity (Icm) is 75 kA at the same voltage range. For coordination studies, these numbers tell you the switch can close onto a fault up to 75 kA peak and hold 50 kA rms for a full second. Impulse withstand voltage is 12 kV, giving solid insulation coordination for 1000 V rated insulation voltage systems.

MPN