Schneider Electric ENW21415

Schneider Electric ENW21415 EasyPact NW Trip System 5.0A Con

MPN ENW21415
Active

Schneider Electric EasyPact NW, Trip System 5.0A control unit, ENW21415, drawout, LSI protection, 800-4000 A, 690 V AC, digital display.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW21415 specifications
ParameterValue
Display typeDigital display
Trip unit typeMicro-processor based
Main product or component typeControl unit
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Depth75 mm
Width55 mm
Height200 mm
Operating temperature-5...70 °C

Product details

What this control unit does

The Schneider Electric ENW21415 is a Trip System 5.0A control unit for the EasyPact NW range of air circuit breakers. It provides LSI protection — long-time, short-time, and instantaneous — for standard industrial applications up to 690 V AC (IEC 60947-2). The microprocessor-based trip unit handles ratings from 800 to 4000 A, with a drawout mounting that lets you swap the control unit without pulling the breaker from the switchgear.

The trip unit rating of 800...4000 A covers the full EasyPack NW frame range — you set Ir (long-time pickup) from 0.4 to 1.0 x In across nine adjustable settings, so the same control unit can be dialed in for a 1000 A feeder or a 3200 A main. The LSI curve is fully programmable: long-time delay Tr from 0.5 to 24 s at 6 x Ir, short-time pickup Isd from 1.5 to 10 x Ir with delay Tsd from 100 to 400 ms, and instantaneous pickup Ii from 2 to 15 x In (or Off). That gives you selective coordination with downstream breakers without sacrificing arc-flash mitigation. The digital display shows instantaneous and maximum current per phase (I1, I2, I3, In) with ±1.5 % accuracy over a 0.2...1.2 In range. Fault indication covers earth fault, short-circuit, overload, and internal fault — no separate ground-fault relay needed for most installations. Zone selective interlocking (ZSI) is built in — when multiple EasyPact NW breakers are daisy-chained, the unit closest to the fault trips instantly while upstream units hold their delay, reducing arc energy. The control unit accepts 50/60 Hz networks and is rated for 3P, 4P configurations with neutral protection settings for 3D, 4D, or 3D + N/2.

Drawout mounting means the control unit slides into the breaker cradle without tools — the neutral connection is on the left side of the unit. Dimensions are 200 mm high, 55 mm wide, 75 mm deep, fitting standard EasyPact NW cubicle cutouts.

MPN
ENW21415