Schneider Electric ENW21415 — Air Circuit Breakers

Schneider Electric ENW21415 EasyPact NW Trip System 5.0A Con

MPNENW21415
Active

Schneider Electric EasyPact NW, Trip System 5.0A control unit, ENW21415, drawout, LSI protection, 800-4000 A, 690 V AC, digital display.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21415 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21415 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P 4P
Network typeAC
Network frequency50/60 Hz
ENW21415 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21415 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

What this control unit does

The Schneider Electric ENW21415 is a Trip System 5.0A control unit for the EasyPact NW range of air circuit breakers. It provides LSI protection — long-time, short-time, and instantaneous — for standard industrial applications up to 690 V AC (IEC 60947-2). The microprocessor-based trip unit handles ratings from 800 to 4000 A, with a drawout mounting that lets you swap the control unit without pulling the breaker from the switchgear.

The trip unit rating of 800...4000 A covers the full EasyPack NW frame range — you set Ir (long-time pickup) from 0.4 to 1.0 x In across nine adjustable settings, so the same control unit can be dialed in for a 1000 A feeder or a 3200 A main. The LSI curve is fully programmable: long-time delay Tr from 0.5 to 24 s at 6 x Ir, short-time pickup Isd from 1.5 to 10 x Ir with delay Tsd from 100 to 400 ms, and instantaneous pickup Ii from 2 to 15 x In (or Off). That gives you selective coordination with downstream breakers without sacrificing arc-flash mitigation. The digital display shows instantaneous and maximum current per phase (I1, I2, I3, In) with ±1.5 % accuracy over a 0.2...1.2 In range. Fault indication covers earth fault, short-circuit, overload, and internal fault — no separate ground-fault relay needed for most installations. Zone selective interlocking (ZSI) is built in — when multiple EasyPact NW breakers are daisy-chained, the unit closest to the fault trips instantly while upstream units hold their delay, reducing arc energy. The control unit accepts 50/60 Hz networks and is rated for 3P, 4P configurations with neutral protection settings for 3D, 4D, or 3D + N/2.

Drawout mounting means the control unit slides into the breaker cradle without tools — the neutral connection is on the left side of the unit. Dimensions are 200 mm high, 55 mm wide, 75 mm deep, fitting standard EasyPact NW cubicle cutouts.

Frequently asked questions

How do I get current pricing and availability for ENW21415?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through our independent distribution channels.

What is the closest alternative to ENW21415 in the EasyPact NW family?

The Trip System 5.0A is the standard LSI control unit for the EasyPact NW range. No pin-compatible alternative exists within the same family — the Trip System 6.0A adds ground-fault protection but uses a different form factor and wiring scheme.

What compliance documentation does this brand provide for ENW21415?

The control unit is rated 690 V AC conforming to IEC 60947-2. Standard Schneider Electric documentation includes a CE declaration of conformity and the product certificate. RoHS and REACH compliance data is available on request.