ENW24104 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24104 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24104 is a 3-pole EasyPact NW circuit breaker rated 1600 A at 40 °C, built for distribution duty in AC networks at 50/60 Hz. Its 50 kA Icu at 220…440 V AC (42 kA at 690 V) tells you it can safely interrupt a fault up to that level without failing — that is the short-circuit capacity that governs selectivity coordination downstream. The Ics (service breaking capacity) matches the Icu at both voltage levels, meaning after clearing a fault at rated breaking capacity the breaker remains functional, not just safe; that is a full-selectivity design, not a sacrificial one. Drawout mounting means the breaker chassis stays wired to the bus while the moving portion pulls out for inspection or swap — no need to disconnect power cables. Rear connection with a 115 mm pitch without spreader matches standard switchgear busbar spacing.

Mounts on a rail in a drawout cradle — the fixed part bolts to the enclosure frame, the moving part slides in. Dimensions: 441 mm wide, 439 mm high, 395 mm deep. That depth matters for enclosure selection — a standard 600 mm deep cabinet leaves enough room for rear cables and the arc chute clearance. Rated insulation voltage 1000 V AC and impulse withstand 12 kV give headroom for 690 V systems. The 25 ms maximum breaking time and 70 ms closing response are coordination parameters — the breaker clears fast enough to let downstream devices ride through a fault without cascading.

MPN
ENW24104