Skip to main content
Schneider Electric EZC100H2045

Schneider Electric EZC100H2045 EasyPact EZC100H, 45 A, 2P, 1

MPN EZC100H2045
Obsolete

Schneider Electric EasyPact EZC100H, 45 A, 2-pole, thermal-magnetic circuit breaker, TM-D trip unit, 10-100 kA breaking capacity, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H2045 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC100H2045 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width50 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC100H2045 is a 2-pole EasyPact EZC100H thermal-magnetic circuit breaker rated 45 A at 40 °C (trip unit TM-D). The 45 A rating at 50 °C means the breaker is calibrated for continuous load at elevated panel temperatures — no derating guesswork for a warm enclosure. Breaking capacity spans 10 kA Icu at 125 V DC (1P) up to 100 kA Icu at 110–130 V AC, with 30 kA at 380–400 V AC and 20 kA at 440 V AC. The 2-pole configuration with front-front connections makes it a direct fit for single-phase or two-wire DC branch circuits in panelboards.

Deployment context

Fixed backplate mounting with a 25 mm connection pitch — this breaker is designed for distribution panels where the busbar spacing matches standard 25 mm centers. IP20 finger-safe terminals and IK07 impact resistance suit it for enclosed panel installation where accidental contact is a concern.

MPN
EZC100H2045