Skip to main content
Schneider Electric EZC100H2045 — Circuit Breaker Accessories

Schneider Electric EZC100H2045 EasyPact EZC100H, 45 A, 2P, 1

MPNEZC100H2045
Obsolete

Schneider Electric EasyPact EZC100H, 45 A, 2-pole, thermal-magnetic circuit breaker, TM-D trip unit, 10-100 kA breaking capacity, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC100H2045 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100H2045 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]45 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description2P
EZC100H2045 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating45 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100H2045 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width50 mm
Height130 mm
Depth60 mm
EZC100H2045 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100H2045 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2

Product details

The EZC100H2045 is a 2-pole EasyPact EZC100H thermal-magnetic circuit breaker rated 45 A at 40 °C (trip unit TM-D). The 45 A rating at 50 °C means the breaker is calibrated for continuous load at elevated panel temperatures — no derating guesswork for a warm enclosure. Breaking capacity spans 10 kA Icu at 125 V DC (1P) up to 100 kA Icu at 110–130 V AC, with 30 kA at 380–400 V AC and 20 kA at 440 V AC. The 2-pole configuration with front-front connections makes it a direct fit for single-phase or two-wire DC branch circuits in panelboards.

Deployment context

Fixed backplate mounting with a 25 mm connection pitch — this breaker is designed for distribution panels where the busbar spacing matches standard 25 mm centers. IP20 finger-safe terminals and IK07 impact resistance suit it for enclosed panel installation where accidental contact is a concern.

Frequently asked questions

Who supplies EZC100H2045 and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is EZC100H2045's listed depth (60 mm) on this component line?

The depth is 60 mm, which fits standard panelboard depth allowances for 2-pole breakers in the EZC100H frame.

What is EZC100H2045's listed width (50 mm) on this component line?

The width is 50 mm, matching the 2-pole module width for EasyPact EZC100H breakers.

What compliance documentation does this brand provide for EZC100H2045?

The breaker is certified to EN/IEC 60947-2, EN/IEC 60947-1, GB/T 14048.2, and JIS C8201-2-2. It carries IP20 and IK07 protection ratings and is suitable for isolation per IEC 60947-2.

MPN
EZC100H2045